Samsung AS24UUQ Manual De Usuario
38
Providing Information for User
Pump Down Procedure (When Removing The Product)
After finishing the installation of the air conditioner, explain the following to
the user:
1 How to start and stop the air conditioner
2 How to select the modes and functions
3 How to adjust the temperature and fan speed
4 How to adjust the airflow direction
5 How to set the timers
6 How to clean and replace the filters
1.
Turn on the air conditioner and select Cool mode to run the compressor
for 3 minutes.
2.
Release the valve caps on High and Low pressure side.
3.
Use L wrench to close the valve on the high pressure side.
4.
Approximately 2 minutes after, close the valve on the low pressure side.
5.
Stop operation of the air conditioner.
6.
Disconnect the pipes.
• When you complete the installation successfully, hand over this manual to the user for storage in a handy and safe
place.