Allen-Bradley devicenet modules in logix5000 control systems Manual De Usuario
Publication DNET-UM004A-EN-P - March 2004
9-16 Communicate with a PanelView™ Standard Terminal
Program the Controller to
Get/Set Explicit Server Tags
Get/Set Explicit Server Tags
To let the controller read/write data from/to an explicit server tag:
Create an Array for the Assembly Instance
For each assembly instance that you use for explicit server tags, create
an array in the RSLogix 5000 project for the data.
an array in the RSLogix 5000 project for the data.
Step:
See page:
Assembly
Instance
3
I:0
16 bits
I:1
16 bits
I:63
16 bits
Array_1[0]
Array_1[31]
Write Tags in PanelView
Array_2[0]
Array_2[31]
Controller Tags
Read Tags in PanelView
Controller Tags
Assembly
Instance
4
O:0
16 bits
O:1
16 bits
O:63 16 bits
Data type = DINT[32]