AMC pm-scc-80 am Manual De Usuario

Descargar
Página de 45
functions will be added in the future. 
z  Use Constant D-01 to select the Auxiliary Relay 1 mode and what it is based on.   
z  Auxiliary Relay 1 Mode includes OFF, ON, Solar Voltage, Output Voltage, 
Battery Voltage (only displayed and active when terminal BVS is connected to 
the battery), Output Current, Battery Current (only active when terminal BCS is 
connected with a Shunt 50mV, 500Amp), Premium MPPT Series Temperature, 
Battery Temperature (only active when terminal BTS is connected with a Battery 
Temperature Sensor, BTS-3), Premium MPPT Series Time and Battery State of 
Charge(only displayed when terminal BCS is connected with Shunt 500Amp, 
50mV). The factory setting is OFF.   
z  D-02, D-03 and D-04 will not be displayed, when D-01 is set to be ON or OFF.   
 
D-02: Aux RY1 ON Condition 
 
z  According to 9 selectable modes in D-01, use Constant D-02 to set the condition 
to activate the Auxiliary Relay 1 to be ON.   
z  The displayed setting range of D-02 will change to less than or greater than (< or 
>) depending on if D-02 or D-03 is higher or lower value. This allows setting on 
either a rising or falling voltage.   
z  Once entering the D-02, use UP and DOWN keys to increment and decrement 
the values.   
Aux RY1 ON Condition 
Setting Range of D-02 
Setting Unit 
When D-01= Solar Voltage 
< or > 0~150V/0~250V 
0.1V 
When D-01=Output Volts 
< or > 0~64V 
0.1V 
When D-01=Battery Volts 
< or > 0~64V 
0.1V 
※  Battery Voltage is only displayed and active when terminal BVS is 
connected to the battery. 
When D-01=OUT Current 
< or > 0~80A 
1A 
When D-01=BATT Current   
< or > -500~500A 
1A 
※  Battery Current is only active when terminal BCS is connected with a 
Shunt 50mV, 500Amp. 
※  The values may be positive or negative as this input reads load current as 
well as charge current.   
When D-01= Premium MPPT 
Series Temp. 
< or > -20~100℃ 
1℃ 
When D-01=Battery Temp. 
< or > -20~100℃ 
1℃ 
※  Battery Temperature is only active when terminal BTS is connected with a 
Battery Temperature Sensor (BTS-3). 
 
5-10