D-04: Aux RY1 MIN. ON time
z Use Constant D-04 is to set the minimum time that the relay can remain active.
z The minimum time is set to avoid the difference of the values set in D-02 and
D-03 is so small to cause the damage on the relay due to the high frequency of
relay action between ON and OFF.
Group E
Auxiliary Relay 2
E-01: Set Aux Relay 2 Mode
E-02: Aux RY2 ON Condition
E-03: Aux RY2 OFF Condition
E-04: Aux RY2 MIN. ON time
E-02: Aux RY2 ON Condition
E-03: Aux RY2 OFF Condition
E-04: Aux RY2 MIN. ON time
※ The functions and the settings of Auxiliary Relay 2 are exactly the same as those
of Auxiliary Relay 1 so please refer to above Group D, Auxiliary Relay 1
description.
Group F
Parallel Setup
F-01: Premium MPPT Series Parallel MODE
z Use Constant F-01 to set up Premium MPPT Series Network. Each Premium
MPPT Series in parallel requires a mode and address entry.
z The Mode choices are:
Setting Usage
Standalone
Used when there is only one Premium MPPT Series with a
Remote Display connected.
Master
Used to assign the network master (this is the Premium MPPT
Series that connects to the shunt).
Slave
Assigns up to 15 additional Premium MPPT Series slave units.
The first Premium MPPT Series is assigned as master and the
rest of units in network are slaves. The network address will be
assigned to each slave unit in F-02.