HP proliant dl580 Manual De Usuario

Descargar
Página de 104
 
Removal and replacement procedures  32 
  IMPORTANT:  The battery pack might have a low charge when installed. In this case, a POST error 
message is displayed when the server is powered up, indicating that the battery pack is temporarily 
disabled. No action is necessary on your part. The internal circuitry automatically recharges the batteries 
and enables the battery pack. This process might take up to four hours. During this time, the cache module 
functions properly, but without the performance advantage of the battery pack.  
  NOTE:  The data protection and the time limit also apply if a power outage occurs. When power is restored 
to the system, an initialization process writes the preserved data to the hard drives. 
 
Removing the BBWC cache module 
1.
 
Power down the server (on page 
2.
 
Extend or remove the server from the rack ("
3.
 
Remove the access panel ("
4.
 
Remove the system cage ("
). 
  CAUTION:  To prevent a server malfunction or damage to the equipment, do not add or remove the battery 
pack while an array capacity expansion, RAID level migration, or stripe size migration is in progress. 
  CAUTION:  After the server is powered down, wait 15 seconds and then check the amber LED before 
unplugging the cable from the cache module. If the amber LED blinks after 15 seconds, do not remove the 
cable from the cache module. The cache module is backing up data, and data is lost if the cable is 
detached. 
5.
 
Open the latches, and remove the BBWC cache module. 
 
6.
 
Disconnect the cable from the cache module. 
To replace the component, reverse the removal procedure. 
 
Removing the system board 
  CAUTION:  Only authorized technicians trained by HP should attempt to remove the system board. If you 
believe the system board requires replacement, contact HP Technical Support before proceeding.