Diagnostic tools  66 
3.
 
Install the expansion boards one at a time, rebooting between each installation to isolate the failed 
expansion board. 
4.
 
Replace the failed expansion board, if applicable. 
5.
 
Replace the PCI riser board, if applicable. 
6.
 
Replace the system board. 
  IMPORTANT:  If replacing the system board or clearing NVRAM, you must re-enter the server serial number 
through RBSU ("
 
Memory-related port 85 codes 
Memory-related port 85 codes display in the format 4xh.  
  IMPORTANT:  Reboot the server after completing each numbered step. If the error condition continues, 
proceed with the next step. 
To troubleshoot memory-related error codes: 
1.
 
) for any identified 
errors or failed DIMMs, and take corrective action. 
2.
 
Bring the server to base configuration by removing all components that are not required by the 
server to complete POST. This process can include removing all: 
 
 
Processors ("
), except the processor installed in socket 1 
  IMPORTANT:  Processor socket 1 and PPM slot 1 must be populated at all times or the server does not 
function properly. 
 
), except the PPM installed in slot 1 
 
DIMMs ("
 
 
Peripheral devices 
3.
 
Reseat the remaining memory boards, rebooting after each installation to isolate any failed memory 
boards, if applicable. 
4.
 
Replace the DIMMs with a remaining bank of memory. 
5.
 
Replace the memory board, if applicable. 
6.
 
Replace the system board. 
  IMPORTANT:  If replacing the system board or clearing NVRAM, you must re-enter the server serial number 
through RBSU ("
 
Miscellaneous port 85 codes 
To troubleshoot all other port 85 codes: 
  IMPORTANT:  Reboot the server after completing each numbered step. If the error condition continues, 
proceed with the next step. 
1.
 
Bring the server to base configuration by removing all components that are not required by the 
server to complete POST. This process can include removing all: