HP proliant dl580 Manual De Usuario

Descargar
Página de 104
 
Server component identification 83 
Activity 
LED (1)  
Online LED 
(2) 
Fault LED 
(3) 
Interpretation 
On Off Off Do not remove the drive. 
The drive is being accessed, but (1) it is not configured as part of an 
array; (2) it is a replacement drive and rebuild has not yet started; or 
(3) it is spinning up during the POST sequence. 
Flashing Flashing Flashing Do not remove the drive. Removing a drive may cause 
data loss in non-fault-tolerant configurations. 
One or more of the following conditions may exist: 
 
The drive is part of an array being selected by an array 
configuration utility 
 
Drive Identification has been selected in HP SIM 
 
The drive firmware is being updated 
Off Off On The drive has been placed offline due to hard disk drive failure or 
subsystem communication failure. 
You may need to replace the drive. 
Off 
Off 
Off 
One or more of the following conditions may exist: 
 
The drive is not configured as part of an array 
 
The drive is configured as part of an array, but it is a 
replacement drive that is not being accessed or being rebuilt yet 
 
The drive is configured as an online spare 
If the drive is connected to an array controller, you may replace the 
drive online. 
 
 
SATA or SAS IDs 
 
  NOTE:  The server may look different from that shown. 
When adding SAS hard drives to the server, observe the following general guidelines:  
 
The server supports eight SAS or SATA hot-plug hard drives. 
 
The system automatically sets all drive numbers.