HP proliant dl580 Manual De Usuario

Descargar
Página de 104
 
Server component identification 85 
Online/activity 
LED (green) 
Fault/UID LED 
(amber/blue) 
Interpretation 
On 
Off 
The drive is online, but it is not active currently. 
Flashing regularly 
(1 Hz) 
Amber, flashing 
regularly (1 Hz) 
Do not remove the drive. Removing a drive may 
terminate the current operation and cause data loss.
 
The drive is part of an array that is undergoing capacity 
expansion or stripe migration, but a predictive failure alert has 
been received for this drive. To minimize the risk of data loss, 
do not replace the drive until the expansion or migration is 
complete. 
Flashing regularly 
(1 Hz) 
Off 
Do not remove the drive. Removing a drive may 
terminate the current operation and cause data loss.
 
The drive is rebuilding, or it is part of an array that is 
undergoing capacity expansion or stripe migration. 
Flashing 
irregularly 
Amber, flashing 
regularly (1 Hz) 
The drive is active, but a predictive failure alert has been 
received for this drive. Replace the drive as soon as possible. 
Flashing 
irregularly 
Off 
The drive is active, and it is operating normally. 
Off Steadily 
amber 
A critical fault condition has been identified for this drive, and 
the controller has placed it offline. Replace the drive as soon as 
possible. 
Off 
Amber, flashing 
regularly (1 Hz) 
A predictive failure alert has been received for this drive. 
Replace the drive as soon as possible. 
Off Off 
The drive is offline, a spare, or not configured as part of an 
array. 
 
 
Fan locations 
The server is shipped with six system fans. Each fan is hot-swappable and independently controlled. The 
fans are distributed into two zones to control thermal conditions within the server. 
 
Zone 1 contains four fans (three, plus one redundant) to control the temperature in the processor 
module area. 
 
Zone 2 contains two fans (one, plus one redundant) to control the temperature in the hard drive bay 
area.