38 
 
 
 
14.5.5  Replacing the Belt of the Motor Reversing Type: RA4R Type 
 
[Items Required for Replacement] 
• Replacement 
belt 
RA4R --- 60S2M152R Rubber, cleanroom type (Bando Chemical Industries) 6 mm wide 
• Allen 
wrenches 
•  Tension gauge (capable of tensioning to 7 kgf or greater) 
•  Strong string, looped (or long tie-band) 
• Scale 
•  Oil-based marker pen 
•  PC or teaching pendant 
 
 
[Overview of Replacement] 
1)  Move the rod to a position where Z phase turns on (home position) (2 mm from the mechanical end). In 
this position, loosen the motor-unit affixing bolts and replace the belt. 
2)  Restore the home position. 
Affix the rod at a position 2 mm from the mechanical end on the home side, pass the belt, and adjust 
the belt to the specified tension. 
3)  Perform homing using a PC or teaching pendant and check for deviation from the initial home position.   
If there is a deviation, adjust the home offset if you are using an SCON controller. If you are using an 
SSEL or X-SEL controller, adjust the home preset. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Home position 
Z phase ON 
position 
Mechanical end 
Approx. 2 mm 
The countermark on the motor 
aligns with this position. 
Set by the home offset parameter (SCON) or home preset parameter 
(SSEL, X-SEL). (The above value indicates the factory setting.) 
1 mm