OKI LP440 Manual De Usuario

Descargar
Página de 76
51
Status LEDs for the Head Check Setting Mode
Head checking can be applied to one of two areas: the 
normal print area and the barcode print area. To specify 
the area subjected to a head check, follow the settings in the 
table below (cover must be left open): 
You can check the current setting with a test printout as 
described in “Performing a Test Print” on page 38.
When setting the Head Check options, the STATUS LED blinks 
green, and turns into a steady green signal upon completion 
of setting. Turn off the printer ONLY when the STATUS LED is 
a steady green light. 
Status LEDs for the Online Command 
Compatibility Mode
The printer can be set for compatibility with SBPL commands 
or with the older MB200 commands. 
You can check the current setting with a test printout as 
H.Check 
setting
DSW-1
DSW-2
DSW-3
DSW-4
Other keys
Normal Print 
Area
OFF
ON
OFF
ON
hold down 
PRINT button
Disable H. 
Check
OFF
ON
OFF
ON
hold down 
FEED button
Barcode Print 
Area
ON
OFF
OFF
ON
hold down 
PRINT button
Disable H. 
Check
ON
OFF
OFF
ON
hold down 
FEED  button
Compatibility
DSW-1
DSW-2
DSW-3
DSW-4 Other keys
LP440-
compatible 
online 
commands
ON
ON
ON
ON
hold down 
PRINT button
SBPL online 
commands
ON
ON
ON
ON
hold down 
FEED button