GE PT878GC Manual De Usuario

Descargar
Página de 308
3-7
April 2004
Performing a Pipe Survey (cont.)
4. Now measure the OD and the wall thickness at eight points 
along the pipe circumference at 45° intervals (shown in Figure 
3-6 below), three times per point, and record the mean values.
Figure 3-6:  Measuring the OD and Pipe Wall Thickness
5. Prepare the pipe for the dampening material by removing any 
rust or loose paint and sanding down any rough spots in an 
area 12 in. long around the circumference of the pipe. Take 
care to preserve the original pipe curvature.
6. At the approximate location of each transducer, prepare an 
area 100 mm (4 in.) long by 50 mm (2 in.) wide for CRV type 
transducers and 100 mm wide for CRW type transducers. 
Remove any paint or rust, and polish the cleared area, taking 
care to preserve the original curvature of the pipe.
OD
1
OD
2
OD
3
OD
4
W
1
W
2
W
3
W
4
W
8
W
7
W
6
W
5