4.6 
Power Budget Calculations for Magnum 6K25 PM’s with Fiber Media 
 
 
Receiver Sensitivity and Transmitter Power are the parameters necessary to 
compute the power budget. To calculate the power budget of different fiber media 
installations using Magnum products, the following equations should be used: 
OPB (Optical Power Budget) = P
T
(min) - P
R
(min) 
      
 where P
= Transmitter Output Power, and P
R
 = Receiver Sensitivity 
 
   Worst case OPB = OPB - 1dB(for LED aging) - 1dB(for insertion loss) 
   Worst case distance = {Worst case OPB, in dB} / [Cable Loss, in dB/Km] 
 
where the “Cable Loss” for 62.5/125 and 50/125
µm
 (M.m) is 2.8 dB/km,  
 
and the “Cable Loss” for 100/140 (Multi-mode) is 3.3 dB/km, 
 
and the “Cable Loss” for 9/125 (Single-mode) is 0.5 dB/km 
 
and the “Cable Loss” for 9/125 (Single-mode) is 0.4 dB/km (LXSC25) 
 
and the “Cable Loss” for 9/125 (Single-mode) is 0.25 dB/km 
(LXSC40) 
 
and the “Cable Loss” for 9/125 (Single-mode) is 0.2 dB/km (LXSC70)
 
 
The following data has been collected from component manufacturer’s (Agilent’s and 
Lucent’) web sites and catalogs to provide guidance to network designers and installers. 
Fiber  
Port 
Module 
Speed, 
 
Std. 
 
Mode
Std. 
km  
fdx 
(hdx)
Wave
-
length
nm 
Cable 
Size 
µ
X’mitr 
Output 
P
T ,
 dB
R’cvr 
Sens.
P
R ,
dB
Worst 
OPB,
dB 
Worst* 
distance 
Km, fdx
typical
OPB,
dB 
typical* 
distance 
Km, fdx 
6KP4-
F10ST
 
10Mb 
FL 
Multi-
Mode
(2) 
850 
62.5/125
100/140
50/125 
-15.0 
-9.5 
-19.5 
-31 
-31 
-31 
14 
19.5 
19.5 
5.9 
3.4 
17 
23.5 
13.5 
6  
4.8 
6KPM- 
MST, MSC 
100Mb
FX 
Multi-
mode
2 
(0.4) 
1300
62.5/125
50/125 
-20 
-23.5 
-31 
-31 
9.0 
5.5 
3.0 
2.0 
14 
12 
6KPM-SS
100Mb
FX 
Single-
mode
18+ 
(0.4)  1300
9/125 -15 -31 14  28 
17.5 
35 
6KPM-
SSCL 
100Mb
FX 
Single-
mode
40 
(0.4)  1300
9/125 -5 -34 
29  58 
32.5 
65 
6KPM- 
MTRJ 
100Mb
FX 
Multi-
mode
2 
(0.4) 
1300
62.5/125
50/125 
-20 
-23.5 
-31 
-31 
9.0 
5.5 
3.0 
2.0 
15.8 
12.2 
5.5 
4.0 
6KPM-
MLC 
100Mb
FX 
Multi-
mode
2 
(0.4)  1300 62.5/125
-19 -31 12 
16 
5.7 
6KPM-SLC 
100Mb
FX 
Single-
Mode
15+ 
(0.4) 
1310
9/125 -15 -28 11  22 
GBIC-
SXSC 
1000Mb Multi-
mode
0.55 
 
1300 62.5/125
50/125 
-9.5 -17 5.5 
12.5 
GBIC-
LXSC10 
1000Mb Single-
mode
10 
1300
9/125 
-9.5 -20 
8.5 
17 
10.5 
21