Operating Parameters
Default
0x00000000
Voice Configuration Menu Access Code
304
ConnectMode
Description
This parameter is a 32-bit bitmap used to control the connection mode of the selected call signaling 
protocol. 
 provides bit definitions for this parameter.
Value Type
Bitmap
Default
0x00060400
Voice Configuration Menu Access Code
311
Table 5-4
ConnectMode Parameter Bit Definitions
Bit Number
Definition
0
0—Use slow-start procedure (for H.225/Q.931 and H.245).
1—Use fast-start procedure (for H.225/Q.931).
1
0/1—Disable/enable h245 tunneling.
2
0—Use the dynamic payload type 126/127 as the RTP payload type (fax pass-through mode) for G.711 
µ-law/G.711 A-law.
1—Use the standard payload type 0/8 as the RTP payload type (fax pass-through mode) for G.711 
µ-law/G.711 A-law.
3
0—Do not perform full gatekeeper registration when the Cisco ATA switches to an alternate H.323 
gatekeeper.
1—Perform full gatekeeper registration when the Cisco ATA switches to an alternate H.323 gatekeeper.
4
0—Denotes a non-Cisco CallManager environment.
1—Enable the Cisco ATA to operate in a Cisco CallManager environment.
5
0/1—Enable/disable two-way cut-through of voice path before the Cisco ATA receives the CONNECT 
message.
6
0/1—Disable/enable using the Progress Indicator to determine if ringback is supplied by the far end with 
RTP.
7
0/1—Disable/enable fax pass-through redundancy.
8-12
Specifies the fax pass-through NSE payload type. The value is the offset to the NSE payload base number 
of 96. The valid range is 0-23; the default is 4. 
For example, if the offset is 4, the NSE payload type is 100.