Using A Booster Battery (Jump Starting)
If it is necessary to use a booster battery to start the
engine, BE CAREFUL! There must be one person in the
operator’s seat and one person to connect and
disconnect the battery cables.
The key switch must be OFF (Key Switch Panel) OR the
STOP Button must be pressed (Keyless Panel). The
booster battery must be 12 volt.
WARNING
Keep arcs, sparks flames and lighted tobacco away
from batteries. When jumping
 from booster battery
make final connection (negative) at machine frame.
Do not jump start or charge a frozen or damaged
battery. Warm battery to 16°C (60°F) before
connecting to a charger. Unplug charger before
connecting or disconnecting cables to battery. Never
lean over battery while boosting, testing or charging.
Battery gas can explode and cause serious injury.
W-2066-0705
Figure 160
Connect the end of the first cable (1) [Figure 160] to the
positive (+) terminal of the booster battery. Connect the
other end of the same cable (2) [Figure 160] to the
positive terminal on the loader starter.
Connect the end of the second cable (3) [Figure 160] to
the negative terminal of the booster battery. Connect the
other end of the same cable (4) [Figure 160] to the
engine. Keep cables away from moving parts. Start the
engine. (See STARTING THE ENGINE on Page 29.)
After the engine has started, remove the ground (-)
cable (4)  [Figure 160] first. Remove the cable from the
positive terminal (2) [Figure 160].
IMPORTANT
Damage to the alternator can occur if:
Engine is operated with battery cables
disconnected.
Battery cables are connected when using a fast
charger or when welding on the loader. (Remove
both cables from the battery.)
Extra battery cables (booster cables) are
connected wrong.