CLR2060 — Clear Ice Maker
www.U-LineService.com
16
02/2005
Electrical Specifications
CAUTION
Electrical installation must observe all state and local 
codes. This unit requires connection to a grounded (three-
prong), polarized receptacle that has been placed by a 
qualified electrician.
The unit requires a grounded and polarized 115 VAC, 
60 Hz, 15A power supply (normal household current). 
An individual, properly grounded branch circuit or circuit 
breaker is recommended. GFCI (ground fault circuit 
interrupter) is usually not required for fixed location 
appliances and is not recommended for your unit because 
a GFCI could be prone to nuisance tripping. However, be 
sure to consult your local codes.
See Figure 41 for recommended receptacle location. 
Plugging the unit into a receptacle located behind an 
adjacent cabinet will allow the CLR2060 to be more easily 
serviced with self-diagnostics without disturbing your 
installation.
WARNING
SHOCK HAZARD — Electrical Grounding Required. 
• Never remove the round grounding prong from 
the plug and never use a two-prong grounding 
adapter.
• Never use an extension cord to connect power to 
the unit.
Go on to 8 Level the Unit.
Leveling Information
IMPORTANT
It is extremely important that the unit is level. If it is not 
level, the ice mold will not fill evenly. 
A unit that is not level can 
cause a reduction in ice rate, 
uneven sized cubes or water 
spilling into the storage 
area, which will cause the ice 
in the bin to melt 
prematurely (see Figure 42). 
Remember that floors near 
drains have a tendency to 
slope towards the drain.
1. Use a level to check the 
levelness of the ice maker 
from front to back and 
from side to side. Level 
should be placed along 
top edge and side edge 
as shown (see Figure 43).
7 Prepare Power Supply
24"
Acceptable
Location
Preferred
Location
for CLR2060
Receptacle
1"
7"
Figure 41
8 Level the Unit
Figure 42
Check
Level
Figure 43