U-Line CLR2060 Manual De Usuario

Descargar
Página de 20
CLR2060 — Clear Ice Maker
www.U-LineService.com
18
02/2005
Installation Troubleshooting
Problem
Q:
Water is leaking under the unit.
Solution
A:
A water leak under the unit is most likely caused by a bad 
connection in the water supply line. Make sure the water 
line’s brass fitting is screwed tight to its valve and 
threaded correctly. Make sure the fill tube’s connection to 
the water line is also tight. Check drain line to make sure 
it has not been disconnected from drain connection on 
back of the unit or disconnected from the drain.
Problem
Q:
The door remains open unless it is pushed closed.
Solution
A:
The hinges should be self-closing when the door is open 
approximately 8". If this is not the case, make sure the 
closers (at the bottom of the hinge pin) are clean, greased 
and installed correctly. Also, re-check leveling from front 
to back of the unit and readjust if necessary. Make sure 
that pivot plate is installed correctly.
Problem
Q:
The custom overlay door was designed to align with the 
rest of the cabinet doors, but the unit has crept forward.
Solution
A:
First, make sure that the electrical cord and water supply 
line are not obstructing the installation. If they are not, 
there is mostly likely not enough room allowed for the 
drain connection on the rear of the unit. You may need to 
alter the wall behind the unit to accommodate the drain 
connection.
Initial Start-Up
Once installation and leveling is complete, the unit is 
ready for initial start-up and operation. The cycle selector 
switch is located in the front grille (see Figure 45). 
1. Open the door and remove the cover in front of the 
evaporator by gently compressing and pulling 
forward. This will enable you to observe the water 
flow over the evaporator.
2. Check that the overflow tube is inserted securely into 
the water trough.
3. Put the cycle selector switch (in the grille) in the ICE 
position (press the switch up). The water fill valve will 
energize and fill the water reservoir. The water fill valve 
shuts off after approximately 180 seconds (3 minutes). 
The compressor begins to operate.
10 Start-Up for the First Time
C
 
E
O
 
F
C
 
L
 
N
C
 
E
O  F
 
F
N
Cycle Selector
Switch
Figure 45