5. Specifications
Nominal voltage
1@5 / 230 V, 50–60 Hz
(selectable)
24 V=/24 V, 50–60 Hz
48 V, 50–60 Hz on request
(selectable)
24 V=/24 V, 50–60 Hz
48 V, 50–60 Hz on request
Rated performance
72 W
Protection class
IP 65 according to DIN 40050
Duty rating
50% at 25°C/30% at 50°C, 20 min
Overload protection
current-time dependent (self resetting)
1)
Electrical connection
unit plug 3 P + GND according DIN 43650
additional cable port PG 11
additional cable port PG 11
Operating time
8 s/90°
쏝)
Operating angle
max. 270°, set at 90°
Nominal torque
60 Nm
Peak torque
200 Nm
Ambient temperature
–10 to +50°C
2)
Allowable humidity
0–98%, non-condensing
Housing material
UP–GF
external screws corrosion-free
external screws corrosion-free
Position indicator
visual, integrated
1)
The overload protection is designed to protect
both motor and power supply board. If the
overload protection device has triggered, it
will reset automatically when the unit has
cooled down sufficiently and the actuator will
operate again.
both motor and power supply board. If the
overload protection device has triggered, it
will reset automatically when the unit has
cooled down sufficiently and the actuator will
operate again.
2)
For temperatures below –10°C the heating
element Nr. 199 190 142/..143 should be
installed (see Item 6.5).
element Nr. 199 190 142/..143 should be
installed (see Item 6.5).
1990_4_Teil3.p65
7.11.2000, 14:29 Uhr
51