georg-fischer ea41 Manual De Usuario

Descargar
Página de 21
¬    ‡
5 1
5.  Specifications
Nominal  voltage
1@5 / 230  V,  50–60  Hz
(selectable)
24  V=/24  V,  50–60  Hz
48  V,  50–60  Hz  on  request
Rated  performance
72  W
Protection  class
IP  65  according  to  DIN  40050
Duty  rating
50%  at  25°C/30%  at  50°C,  20  min
Overload  protection
current-time  dependent  (self  resetting)
1)
Electrical  connection
unit  plug  3  P  +  GND  according  DIN  43650
additional  cable  port  PG  11
Operating  time
8  s/90° 
쏝)
Operating  angle
max.  270°,  set  at  90°
Nominal  torque
60  Nm
Peak  torque
200  Nm
Ambient  temperature
–10  to  +50°C
2)
Allowable  humidity
0–98%,  non-condensing
Housing  material
UP–GF
external  screws  corrosion-free
Position  indicator
visual,  integrated
1)
The  overload  protection  is  designed  to  protect
both  motor  and  power  supply  board.  If  the
overload  protection  device  has  triggered,  it
will  reset  automatically  when  the  unit  has
cooled  down  sufficiently  and  the  actuator  will
operate  again.
2)
For  temperatures  below  –10°C  the  heating
element  Nr.  199  190  142/..143  should  be
installed  (see  Item  6.5).
1990_4_Teil3.p65
7.11.2000, 14:29 Uhr
51