BMI Technologies Inc. VUI00 Manual De Usuario

Descargar
Página de 52
DRAFT G FORCE PLUS & G FORCE PLUS RF Instruction Manual 
 
 
Doc #RF1 Rev.2 
15 
Nov 2005 
Component Overview 
 
 
 
Installation Steps 
 
Follow the steps in the order below and refer to diagram in 
Component Overview
1.  Mount the Transceiver in the selected location. 
 Note:  This device exceeds the FCC/IC requirements for RF exposure when the antenna used for 
this transmitter has a separation distance of at least 20 cm from all persons and must not be co-
located or operating in conjunction with any other antenna or transmitter which is closer than 20 
cm. The installer of this radio equipment must ensure that the antenna is located or pointed such 
that it does not emit RF field in excess of Health Canada limits for the general population as 
indicated by Safety Code 6.
 
 Note:  The provided antenna, which operates in the 902 to 928 MHz frequency band, and antenna 
extension cable, must be used with the G FORCE PLUS RF Vehicle Monitor.  No substitutions 
are allowed.
 
 The optimal location for a Transceiver and antenna is:  
  Where it will be safe from environmental hazards, possible impacts, and vandalism, 
  As high as possible from the floor, 
  At least two feet away from any large metal mass for best communications results. 
 Use the base of the Transceiver as a template to drill four ¼-inch holes in the selected location 
and attach the Transceiver using the hardware provided. 
 
2.  Mount and connect the antenna. 
 Attach the metal bracket provided to the selected location so the antenna will be vertical
 Insert the antenna into the bracket slot and secure the antenna by tightening the nut.