BMI Technologies Inc. VUI00 Manual De Usuario

Descargar
Página de 52
DRAFT G FORCE PLUS & G FORCE PLUS RF Instruction Manual 
 
 
Doc #RF1 Rev.2 
13 
Nov 2005 
  Blue wires – lift interrupt:  Use these wires to interrupt the lift solenoid on battery-powered 
vehicles if desired.  The contact on the blue wires is fused at 3 amps – do not create a circuit 
that exceeds this rating.  Remove one vehicle wire at the coil of the lift solenoid.  Splice one 
blue wire to the wire just removed.  Connect the other blue wire to the vehicle lift solenoid 
terminal.  Tie these wires back if they are not used, or if this is an internal-combustion vehicle 
installation. 
 
 
  Purple wires – secondary alarm: Use these wires to create a secondary alarm if desired.  
The contact on the purple wires is fused at 3 amps – do not create a circuit that exceeds this 
rating.  Contact BMI Technologies Inc. at 1-800-563-8867 for technical assistance for your 
particular installation.  Tie these wires back if they are not used. 
 
Test the installation. 
 Reconnect the battery and turn on the vehicle ignition to test the installation. 
 The vehicle should power up and the Vehicle Interface should indicate that the Vehicle Monitor 
is in Maintenance Lockout. 
 Lift operation should be interrupted if the blue wires were connected for lift interrupt. 
 The vehicle’s behavior should reflect a secondary alarm condition if the purple wires were 
connected for a secondary alarm. 
 
 
 
 
 
 
Complete or pause the installation. 
 Refer to the section 
VEHICLE MONITOR INITIALIZATION
 to program the Vehicle Monitor 
settings, or 
 Disconnect the Vehicle Monitor and Wiring Harness and reconnect the Installation Bypass Plug 
to the end of the Wiring Harness to allow full vehicle use and to defer the programming of 
Vehicle Monitor settings. 
 
SOFTWARE AND INTERFACE 
 
PC Software and Interface installation may be done at the same time as the Vehicle Monitor and Interface 
installation.  The Software Interface must be installed before the software is installed. 
NOTE! 
If the installation test fails,  
contact BMI Technologies Inc. at 1-800-563-8867.