BMI Technologies Inc. VUI00 Manual De Usuario
DRAFT G FORCE PLUS & G FORCE PLUS RF Instruction Manual
Doc #RF1 Rev.2
37
Nov 2005
PREVENTATIVE MAINTENANCE
DATA COLLECTION
Data collected from a Vehicle are referred to as Events. Events are accumulated in the memory of a Vehicle
Monitor and provide the following details about the Vehicle:
Logins – Vehicle, Operator, login date/time, login duration
Passed Vehicle Inspections – Vehicle, Operator, date/time of completion, passed items
Failed Vehicle Inspections – Vehicle, Operator, date/time of failure, passed items, failed item
Impacts – Vehicle, Operator, Impact date/time, type and threshold, Supervisor
Battery – Vehicle, Operator, date/time of battery state change, battery state
Maintenance – Vehicle, Employee, Lockout or Unlock, date/time of Lockout or Unlock
Hot Card – Vehicle, date/time of Hot Card use, and Supervisor
In the G FORCE PLUS system Events are collected from Vehicles using the Data Logger and then
downloaded to the software from the Data Logger. In the G FORCE PLUS RF system, Events are transmitted
to the Fleet Manager software by means of the RF Transceiver link (the Data Logger is used as a backup
means of data collection only).
Collect Data from a Vehicle
9. Place the Vehicle into Maintenance Lockout (see
Manually Lockout a Vehicle
).
10. Press Enter to start the Data Logger.
11. Press 4 when the LCD displays “Action?(1-9)”. The LCD will display “Action?(1-9) Events
11. Press 4 when the LCD displays “Action?(1-9)”. The LCD will display “Action?(1-9) Events
from Veh”
12. Press Enter to accept the choice. The LCD will display “Ready for Events”
13. Present the Data Logger to the Vehicle Interface.
14. Listen for a sequence of three quick beeps to indicate the interaction is complete.
15. Remove the Data Logger from the Vehicle Interface. The Vehicle Interface LCD will display
13. Present the Data Logger to the Vehicle Interface.
14. Listen for a sequence of three quick beeps to indicate the interaction is complete.
15. Remove the Data Logger from the Vehicle Interface. The Vehicle Interface LCD will display
“MAINT LOCK OUT YYYY/MM/DD HH:MM”
16. Press Cancel on the Data Logger. The LCD will display “Action?(1-9)”
17. Remove the Vehicle from Maintenance Lockout (see
17. Remove the Vehicle from Maintenance Lockout (see
Remove a Vehicle from Lockout
).
Download Data to the Software
5. Press
Enter to start the Data Logger.
6. Press
1 when the LCD displays “Action?(1-9)”. The LCD will display “Action?(1-9) Events to PC”
7. Press
Enter to accept the choice. The LCD will display “Ready for PC”
8. Present the Data Logger to the Software Interface.
9. Start the Fleet Manager software (optionally select the Events tab).
9. Start the Fleet Manager software (optionally select the Events tab).
NOTE!
If the Data Logger is removed from the Vehicle Interface too soon,
six quick beeps will sound. Return the Data Logger to the Vehicle
Interface to begin data collection again. No data has been lost.