DRAFT G FORCE PLUS & G FORCE PLUS RF Instruction Manual 
 
 
Doc #RF1 Rev.2 
35 
Nov 2005 
In this state, the Vehicle Interface will display “VEHICLE SYSTEM CHECK PLS WAIT..”. 
  
Operator Login 
 
After the Diagnostic Delay timer expires, the Vehicle enters Operator Login state.  The Vehicle Interface 
will display “OPERATOR LOGIN PRESENT CARD” and is waiting for an Operator Card or 
Maintenance Lockout Card to be presented.  
 
The Vehicle Interface will display one of the following: 
 
MESSAGE MEANING 
LOGIN DECLINED: CARD INVALID 
Not a valid Operator Card 
Not a valid Lockout Card 
LOGIN DECLINED: CARD EXPIRED 
 
LOGIN DECLINED: NOT 
AUTHORIZED 
 
LOGIN APPROVED: CARD EXPIRY 
SOON 
 
LOGIN APPROVED 
 
HOT CARD! CONTACT SUPERVSR 
 
 
After a successful login, the Vehicle will enter Operating state, or if a Vehicle Inspection is required, it 
will enter the Vehicle Inspection state.  A Login Event is written to the Event memory of the Vehicle 
Monitor.   
 
Keying off the Vehicle completes a Vehicle operator’s login session. 
 
A Vehicle must be keyed off and back on again in order to allow a new Vehicle operator to log in. 
 
 
 
Hot Card 
 
If a Card is presented that is on the Hot Card List, the Vehicle enters the Hot Card state.  A Supervisor 
Card must be presented to the Vehicle Interface to return the Vehicle to Operator Login state.  A Hot Card 
Event is written to the Event memory of the Vehicle Monitor. 
 
A Vehicle remains in Hot Card state even if it is keyed off.  When it is keyed on again, the Hot Card state 
resumes. 
 
Vehicle Inspection 
 
If a Vehicle Inspection is required, the Vehicle will enter the Vehicle Inspection state after a successful 
Operator login. 
 
The Inspection Checklist is displayed on the Vehicle Interface, one item at a time.  In order to move to the 
next item on the checklist, the Operator must press Pass on the Vehicle Interface.  After all items on the 
list have been passed, the Vehicle enters Operating state. 
 
In order to fail an item on the checklist, the Operator must press Fail.  The Operator will be asked to 
confirm the failure of the item by pressing Fail a second time.