Simoco EMEA Ltd SDB670AC01 Manual De Usuario

Descargar
Página de 56
SDB670 – SERVICE MANUAL 
TNM-M-E-0032 
May 13 
Page 24 
DESCRIPTION 
These  units  are  electrically  identical  to  the  SDM600  Mobile  and  are  also  fully  interchangeable  in 
the 25 W power group.  Control is provided via the 10-way RJ45 connector.  Power is supplied via 
the  power  harness  connector  and  RF  signals  are  coupled  to  the  British  Naval  Connector  (BNC) 
sockets with double-screened cables. 
4.2  F
RONT 
P
ANEL
 
The SDB670 front panel is illustrated below in Figure 4
Figure 4.  SDB670 Front Panel. 
4.2.1 
LED Indicators 
On the front of the SDB670 base station there are 12 Light Emitting Diode (LED) indicators.  There 
details are explained below in Table 7
Table 7.  Details of Front Panel LED Indicators. 
LED 
Legend  Colour 
Description 
Health 
Ì 
Green 
Indicates  
Func 1 
VM 
 
For Tier II this is a programmable function. 
For Tier III this indicates the base is a VAC Master 
Func 2 
SM 
 
For Tier II this is a programmable function. 
For Tier III this indicates the base is a Site Master. 
 
 
 
Indicates base is in Analogue Mode 
Rx 1 
R1 
 
Indicates signal received on Slot 1 
Tx 1 
T1 
 
Indicates unit is keyed up and transmitting on Slot 1 
Power 
 
 
Indicates the presence of electrical supply voltage. 
Tx 2 
T2 
Red 
Indicates unit is keyed up and transmitting on Slot 2 
Rx 2 
R2 
Yellow 
Indicates signal received on Slot 2 
 
 
 
Indicates base is in DMR Mode 
Func 3 
IS 
Orange 
For Tier II this is a programmable function. 
For Tier III this indicates the base is an Isolated Site. 
Func 4 
IB 
Orange 
For Tier II this is a programmable function. 
For Tier III this indicates the base is an Isolated Base. 
Alarm 
 
Red 
Indicates a pre-arranged alarm condition exists. 
 
4.3  R
EAR 
P
ANEL 
C
ONNECTORS
 
The rear panel of the SDM670 DMR base station showing all the external connections for both the 
AC and DC version are shown overleaf in Figures 5 and 6.  The functions of each connector on 
the rear panel are detailed in Table 8