Simoco EMEA Ltd SDB670AC01 Manual De Usuario

Descargar
Página de 56
SDB670 – SERVICE MANUAL 
TNM-M-E-0032 
May 13 
Page 25 
DESCRIPTION 
Figure 5.  Layout of Rear Panel (AC version). 
Figure 6.  Layout of Rear Panel (DC version). 
Table 8.  Rear Panel Connections. 
Connector #  Conn Type 
Function 
Description 
 
 
Power I/P 
13.8 V DC power input 
S2 
RS232 
Serial Port 
 
S1 
D Type 
Facilities 
 
P5 
RJ45 
Ethernet 
10/100 base-T RJ45 Ethernet connector 
P4 
USB Type B 
Peripheral 
USB peripheral interface 
P3 
USB Type A 
Host 
USB interface 
 
 
Battery Backup 
 
Tx 
N Type 
Tx O/P 
RF Power output from the Tx 
Rx 1 
BNC 
Rx I/P 
Rx input for full duplex operation 
 
4.3.1 
Tx/Rx Connections 
The  Tx antenna connection on the DMR Base is provided with 50 Ω female N-type socket, while 
for the Rx antenna connection a BNC socket is used. 
The Tx antenna cable connection must be made with 50 Ω N-type on a flexible tail.  The Voltage 
Standing Wave Ratio (VSWR) of Tx and Rx connections should be tested prior to use by using of a 
suitable test set, e.g. an Anritsu/Wiltron S331A.  A good VSWR of 1.5:1 or better at the relevant Tx 
and Rx frequencies should be ensured. 
Mating  connectors  should  be  galvanically  compatible  with  nickel  outer  and  gold  centre  pin  to 
minimise passive intermodulation. 
A  minimum  of  85  dB  transmit-receive  isolation  should  be  provided  by  the  antenna  system  and 
associated filters. 
It  is  recommended  that  a  good  quality  flexible  co-axial  cable  is  used,  e.g.  with  double-screening 
braid and multi-strand copper inner.