TAG-T3 Wombat – User Guide, 1.0.7  
Commands
 
 
4.3.5   Power (Configuration) 
 
Sets or resets the monitoring of the power available to run the unit. For 
battery powered units it should be used to count down the available 
power of the battery. 
 
$GO0,,POW,<amps> 
 
$GOA,<Unit_Id>,POW,<amps> 
 
Power (Configuration) Command
 
Description 
amps 
Initial amount of power available 
in amp hours 
Table 8, Power (Configuration) Command 
 
Default:  
$GO0,,POW,0 
 
Example: 
$GO0,,POW,10.0 
 
Returns:  
$GOA,<Unit_Id>,POW,10.0 
 
If the available power is set to zero the power used will count up from 
zero. If available power is set to a number then the power used will 
count down. 
 
4.3.6  Backdoor 
 
Turns on or off the TRX midnight backdoor. Backdoor is referenced to 
local time. 
 
Note:  The midnight backdoor is provided to ensure there is one period 
each day that the device can be contacted by TRX even if 
parameters are set to values which would prohibit the TRX 
coming on. Only experienced users should disable the backdoor.
 
 
$GO0,,BDR[,ON|OFF] 
 
$GOA,<Unit_Id>,BDR,ON|OFF 
 
Backdoor Command
 
Description 
ON|OFF 
Turns Backdoor setting ON or OFF 
Table 9, Backdoor Command 
 
Default:  
$GO0,,BDR,ON 
 
Example: 
$GO0,,BDR,OFF 
 
Returns:  
$GOA,<Unit_Id>,BDR,OFF 