Geonautics International Pte Ltd 30-0710 Manual De Usuario
TAG-T3 Wombat – User Guide, 1.0.7
Commands
4.3.5 Power (Configuration)
Sets or resets the monitoring of the power available to run the unit. For
battery powered units it should be used to count down the available
power of the battery.
battery powered units it should be used to count down the available
power of the battery.
$GO0,,POW,<amps>
$GOA,<Unit_Id>,POW,<amps>
Power (Configuration) Command
Description
amps
Initial amount of power available
in amp hours
in amp hours
Table 8, Power (Configuration) Command
Default:
$GO0,,POW,0
Example:
$GO0,,POW,10.0
Returns:
$GOA,<Unit_Id>,POW,10.0
If the available power is set to zero the power used will count up from
zero. If available power is set to a number then the power used will
count down.
zero. If available power is set to a number then the power used will
count down.
4.3.6 Backdoor
Turns on or off the TRX midnight backdoor. Backdoor is referenced to
local time.
local time.
Note: The midnight backdoor is provided to ensure there is one period
each day that the device can be contacted by TRX even if
parameters are set to values which would prohibit the TRX
coming on. Only experienced users should disable the backdoor.
parameters are set to values which would prohibit the TRX
coming on. Only experienced users should disable the backdoor.
$GO0,,BDR[,ON|OFF]
$GOA,<Unit_Id>,BDR,ON|OFF
Backdoor Command
Description
ON|OFF
Turns Backdoor setting ON or OFF
Table 9, Backdoor Command
Default:
$GO0,,BDR,ON
Example:
$GO0,,BDR,OFF
Returns:
$GOA,<Unit_Id>,BDR,OFF
© Geonautics
24
Law Enforcement ONLY