TAG-T3 Wombat – User Guide, 1.0.7  
Commands
 
 
4.3.4  Voltage 
 
Set the trigger levels for voltage rises and voltage drops.  The duration 
of the trigger is set by the duration time of the Motion (Configuration) 
command. See page 22. 
 
 
$GO0,,VLT[,<low>][,<high>] 
 
$GOA,<Unit_Id>,VLT,<low>,<high> 
 
Voltage Command
 
Description 
low 
Lower voltage trigger level expressed as volts*10 
high 
Upper voltage trigger level expressed as volts*10 
Table 7, Voltage Command 
 
Default:  
$GO0,,VLT,0,135 
 
Example: 
$GO0,,VLT,20,120 
 
Returns:  
$GOA,<Unit_Id>,VLT,20,120 
 
 
 
A voltage setting of 135 is interpreted as 13.5 volts. 
 
When setting the high limit to sense the alternator induced voltage 
rise, use the Parameter, page 42, 
or Debug (Last), page 44, command 
to establish the voltage when the engine is running and then set the 
high value to a voltage slightly under that voltage (0.3 volts lower is 
normally sufficient). 
 
 