Honeywell International Inc. WFSLCDUI Manual De Usuario
PRELIMINARY: Firelite Wireless Sensor Network P/N LS10036-000FL-E:N0 10/10/2013
23
Configuration and Programming
W-GATE
Mesh Formation with PC Tools
To create a mesh network using the PC Tools, perform the following steps.
1.
Connect the W-USB dongle device to your computer. For more information on USB dongle,
refer to Section 5:, "USB Adapter".
refer to Section 5:, "USB Adapter".
2.
Launch the PC tools application. Refer to Appendix B:, "PC tools" to know about launching
the PC tools application.
the PC tools application.
3.
Go to Create Mesh Network step.
4.
Navigate to the second step of Create Mesh Network by clicking
on top of the screen.
5.
Click to select the W-GATE displayed in the Gateways in Range table, and click 'Start Mesh
Formation'.
Formation'.
When the mesh is formed, the tool helps you to track the number of devices that have joined the
mesh, and view the progress. The mesh formation terminates 10 minutes after the last device joins
the mesh. In addition, it can be terminated by the user by clicking Stop Mesh Formation.
mesh, and view the progress. The mesh formation terminates 10 minutes after the last device joins
the mesh. In addition, it can be terminated by the user by clicking Stop Mesh Formation.
Once mesh formation is complete, the network transitions to optimize the mesh. For further operat-
ing instructions, refer to 2.7, "Operations".
ing instructions, refer to 2.7, "Operations".
2.6.3 Profile Distribution
There are two ways to initiate profile distribution from the W-GATE.
•
Automatically after creating a profile,
•
Activating the profile creating magnetic sensor when it has a profile.
After Creating a Profile
Profile distribution is automatically enabled from the W-GATE after creating a profile. The profile
distribution automatically terminates after 10 minutes.
distribution automatically terminates after 10 minutes.
Activating the Profile Magnetic Sensor When it has a Profile
Activating the profile magnetic sensor while it
has profile will put the W-GATE in a mode of
distributing the profile to any device that
requests a profile. The W-GATE’s LED pattern
will be altered when it is distributing a profile
for easy identification. Profile distribution will
automatically terminate after 10 minutes. For
more information on W-GATE LED patterns,
refer to the table in 2.7.3, "LED Indications".
has profile will put the W-GATE in a mode of
distributing the profile to any device that
requests a profile. The W-GATE’s LED pattern
will be altered when it is distributing a profile
for easy identification. Profile distribution will
automatically terminate after 10 minutes. For
more information on W-GATE LED patterns,
refer to the table in 2.7.3, "LED Indications".
Figure 2.9 Profile Magnetic
Sensor on a W-GATE