4.5 
Antenna 
4.5.1 
Overview 
The Paragon4 unit commonly uses three antennas (one transmit and two receive) unless a duplexer is 
used with one of the receive antennas; then only two antennas  would be needed. If the 10MHz Dis-
ciplined  Clock  option  is sought,  there  is  another  GPS  antenna  in  addition to the  three  already  men-
tioned. They should be mounted according to any guidelines supplied with the antennas. For antennas 
placement and spacing, consult System Engineering.  
 RF exposure warning:
 
To comply with IC, the antenna(s) must be installed to provide a seperation distance from nearby 
persons as determined by the following formula or 20 cm whichever results in the greatest sepa-
ration distance. R > (PxG/6.5)^0.5 cm. P=transmitter power in milli-watts, G=numeric antenna 
gain."
 
4.5.2 
Cabling and Connection 
1-  Route good quality 50-ohm double-shielded coaxial cable(s) (e.g. RG-214 or Heliax) from the se-
lected antenna position(s) to the Paragon4 Radio assembly. 
2-  Referring to Figure 3 for locating modules, terminate the RX-1 and RX-2  cable-ends at their re-
spective rear position of the receiver  module with N-type connectors. 
3-  Similarly,  terminate  the  TX  cable-end  at  the  rear  position  of  the  Power  Amp’s  module  with  an 
N-type connector. 
Caution:  
When terminating RF cables use brand-name crimping tools (such as AMP, Jensen, 
Crimp-Master, etc…) of the correct size for the cable and type of connector used. 
Common pliers are NOT acceptable. 
4.6 
Completing the physical Installation 
Paragon4 products are factory-configured to user’s requirements and are shipped ready to run.  
After new installations: 
  Re-check  that  all  connections  are  secure  on  the  radio-modem  assemblies  (antennas,  PC,  power 
cords etc.) 
  Check that fuses are inserted. 
  Turn power supply ON. 
You are now ready to check for normal operation (as per paragraph 4.7) and to run the Dataradio web 
interface (described in section 6) for testing or trouble-shooting.  
 
4.7 
Checking out Normal Operation 
1-  Check that power is applied. 
2-  Check Radio assembly lights for proper operation as per section 5.1 
3-  Check for proper operation of the BSC2 LEDs. 
4-  Using  the  web  interface  program  and  an  in-line  wattmeter,  check  forward  &  reverse  power  to 
confirm main antenna installation. 
5-  Using the web interface, check the RF Data Link with a mobile that can be heard. 
If user application and mobiles are available, test the installation by going through a normal sequence 
of transmitting and receiving messages.