FlexWave Prism Remote Unit RF Module Installation Guide
Page 23
TECP-77-141 Issue 8  •  300001744178 Rev H  •  August 2015
©2015 TE Connectivity
Remove Release Liners from the RF Module
NOTE:
Release Liners are present on front and back of new modules.
1
Open the Remote Unit enclosure.
2
Remove release liners, if present, from the thermal pads on the RF Module prior to installing the module into 
the Remote Unit chassis.
CAUTION! The thermal pads are very sensitive to mishandling—do not nick, scratch, or ding them.
For Single- and Dual-Bay RF Modules, the thermal pads are located as listed below and as shown in 
which shows a Legacy Dual-Bay 40W RF Module.
one large pad on the back surface of each Linear Power Amplifier (LPA)
up to two on the front surface (DARTs)
one on the left side for the (RDI)
one on the vector modulator board
One large
thermal pad on each PA
(boom of the LPA)
One thermal pad
for the RDI
One thermal pad
for each DART
One thermal pad
for each DART
One thermal pad
for RF Power
Combiner
One thermal pad
for Vector
Modulator
one on the RF power combiner.
Figure 9. Thermal Pads on a Legacy Dual-Bay 40W RF Module