IT2410 Tag Programmer User Guide
D-14
Table D-8  Values for Programmer Configuration Bit
All the factory defaults for the programmer and the configuration parameters restored 
from NVRAM or from factory defaults are shown in Table D-9.
Table D-9  Factory Default Configuration Parameters
Reset Programmer
The Reset Programmer command causes all the programmer parameters to initialize 
to a power-up state (based on the NVM settings) and forces the internal logic card 
power-on diagnostics to be initiated (Table D-10).
Table D-10  Reset Data
Value
Definition
0
Factory defaults
1
Nonvolatile memory (NVRAM)
Parameter
Programmer Factory Defaults
RF frequency
914.75 MHz
RF attenuation level
0 (fixed attenuation)
a
a.  
The programmer is designed so that the RF attenuation is fixed in the firm-
ware to a setting of 0 dB, however, there is a fixed attenuation in the RF 
module to allow limited functional range of approximately 0.5 ft (0.15 m) 
for the built-in antenna.
Communications baud rate
38,400 bps
Check tag configuration
N/A
Tag response append data
N/A
Tag command mode
N/A
Custom auto tag command table
N/A
Custom auto user sequence table
N/A
Programmer control
Tag command time-out 10 seconds, buzzer 
enabled
Byte
Bit 7
0
Reset control (most significant byte)
1
Reset control (least significant byte)