D-23
Network mask — Must be specified in valid dot format, such as 10.3.10.10.
MAC address — Must be specified in valid dash format, such as 00-01-02-03-04-05. 
MAC address can only be set during factory setup.
All parameters must be passed in C-string format, including 0 (NULL) terminating 
byte (Table D-21). N represents the C-string length, not including terminating byte.
Get/Set Programmer RF
The Get Programmer RF requests the frequency setting from the host. The Set Pro-
grammer RF sets the frequency. Data associated with the tag programmer RF is listed 
in Table D-22.
Transceiver RF Frequency — This byte represents the transceiver RF. Table D-23 
lists the valid frequencies.
Table D-21  C-String Format for Parameters
Command Bytes
Data
0
Subcommand
1-(N+1)
Data string, such as 10.3.10.10 or
 
00-01-02-03-04-05.
(N+1)+1
00H
Table D-22  Programmer RF Data
Byte
Bits 7 - 0
0
Reserved
1
Transceiver RF
Table D-23  Valid Transceiver Frequencies
Byte Value
Frequency (MHz)
2BH
912.75
2FH
913.75
33H
914.75
37H
915.75
3BH
916.75
3FH
917.75
43H
918.75