Installation Manual
ELECTRICAL / NETWORK INSTALLATIONS
Access to Power 
• 
The gateway requires access to power and can use either a 120V AC grounded outlet for use with the AC-to-DC 
power supply and power cord (66528-003), or a DC power source to be used with the DC power source cable with 
308 in-line connector . For a gateway with a LAN PoE configuration, a Power over Ethernet connection is required . 
• 
Outlet and enclosure (if required) should be mounted for easy accessibility by authorized utility personnel at the 
installation site . 
• 
Consult appropriate electrical, building and industry codes, regulations and standards for accepted installation 
practices for use of the AC-to-DC power supply and outlet in environmentally controlled indoor locations . 
Use of a NEMA 4 Enclosure
AC-to-DC power supply used outdoors or in a non-environmentally controlled indoor location requires a customer-supplied 
NEMA 4 enclosure, or equivalent, be installed in accordance with appropriate electrical codes, building codes, industry codes, 
regulations and standards .
CDMA or GPRS Recommended Installation
AC to DC Power Supply with 
308 In-line Connector End and 
Power Cord  (supplied)
120VAC   
Grounded Outlet       
(customer 
supplied)
Power Supply Cable with 
308 In-line Connector
Power Cable with 
308 In-line Connector 
(supplied)
Figure 17:   CDMA or GPRS connection with AC power source (*Shown with NEMA 4 enclosure)
*An enclosure may be recommended but is not included .
If NEMA 4 enclosure or equivalent is required, the minimum enclosure size is 12" x 10" x 6" (H x W x D) .