Figure 2-3 LPU & PAB Numbering Front View
PA modules in the PAB’s are installed in two orientations. The upper modules are
installed with the cooling fins up. The lower PAB modules are installed with the cooling
fins down. Fully seat each module by pressing firmly against the outside front edges on
the handles. Do not press (or pull) on the center of the handle as it may deform.
installed with the cooling fins up. The lower PAB modules are installed with the cooling
fins down. Fully seat each module by pressing firmly against the outside front edges on
the handles. Do not press (or pull) on the center of the handle as it may deform.
!
CAUTION:
IF THE MODULES DO NOT SEAT WITH MODERATE PRESSURE, REMOVE THE
MODULE TO CHECK FOR INTERFERENCE. DO NOT FORCE THE MODULES INTO
THE CHASSIS AS THIS MAY CAUSE DAMAGE TO THE RF CONNECTOR ON THE
BACK OF THE MODULE OR ON THE PA BACKPLANE BOARD.
MODULE TO CHECK FOR INTERFERENCE. DO NOT FORCE THE MODULES INTO
THE CHASSIS AS THIS MAY CAUSE DAMAGE TO THE RF CONNECTOR ON THE
BACK OF THE MODULE OR ON THE PA BACKPLANE BOARD.
STEP 3
Check the two satellite receivers and IRD units for security.
STEP 4
Install the coaxial line assemblies at the input and output of the
mask filter.
STEP 5
Install the RF sample cables on the directional coupler located at the
filter input. The location of these cables is described in the Wiring
Diagram, UAX 2kW Dual Drive with TCU Racked, drawing number
843-5602-409 which can be found in the 917-2323-240 drawing
package which is part of the 988-2693-004 documentation package.