GatesAir Inc. UAXFLID Manual De Usuario

Descargar
Página de 46
10/6/10
888-2721-001
2-5
 
WARNING: Disconnect primary power prior to servicing.
Section 2 Installation / Initial Turn-On 
Maxiva UAX Transmitter Indoor System
User Manual
Figure 2-3  LPU & PAB Numbering Front View
PA modules in the PAB’s are installed in two orientations. The upper modules are 
installed with the cooling fins up. The lower PAB modules are installed with the cooling 
fins down. Fully seat each module by pressing firmly against the outside front edges on 
the handles. Do not press (or pull) on the center of the handle as it may deform.
!
 CAUTION:
IF THE MODULES DO NOT SEAT WITH MODERATE PRESSURE, REMOVE THE 
MODULE TO CHECK FOR INTERFERENCE. DO NOT FORCE THE MODULES INTO 
THE CHASSIS AS THIS MAY CAUSE DAMAGE TO THE RF CONNECTOR ON THE 
BACK OF THE MODULE OR ON THE PA BACKPLANE BOARD.
STEP 3
Check the two satellite receivers and IRD units for security.
STEP 4
Install the coaxial line assemblies at the input and output of the 
mask filter. 
STEP 5
Install the RF sample cables on the directional coupler located at the 
filter input. The location of these cables is described in the Wiring 
Diagram, UAX 2kW Dual Drive with TCU Racked, drawing number 
843-5602-409 which can be found in the 917-2323-240 drawing 
package which is part of the 988-2693-004 documentation package.