WARNING: Disconnect primary power prior to servicing.
Section 2 Installation / Initial Turn-On
Maxiva UAX Transmitter Indoor System
User Manual
2.4
Installation of Components Removed for Shipment
Selected components have been removed for shipment following factory assembly and 
test. These components have been packed separately and should be unpacked as needed 
for reassembly.  These items must be stored in a safe, climate controlled, dry location 
until needed for reassembly. Save all packing material until after commissioning to 
facilitate returns if needed. Notify Harris immediately if damage is noted while 
unloading the shipment.
The removed components include:
Removed from the front of the transmitter (and identified in Figure 1-2 on page 1-4) are 
two Satellite receivers and IRD’s, router, power amplifier modules in the LPU’s and 
power amplifier blocks, and the mask filter. 
Coaxial lines into and out of the mask filter may have been removed from the rear of the 
transmitter rack. 
STEP 1
Install the mask filter in the front of the cabinet and secure it in 
position.
STEP 2
Install the power amplifier blocks in the LPU’s and in the power 
amplifier blocks. Read Section 2.4.1 Install PA Modules before 
installing PA modules.
2.4.1
Install PA Modules
The PA Modules should be placed into the Low Power Unit (LPU) and Power 
Amplifier Block (PAB) at this time. They should be inserted into the module slots in 
which they were tested. In the LPU the PA modules are inserted with the cooling fins 
up. Each module has a serial number which is recorded on the factory test data sheet as 
belonging to a specific module slot, in the LPU or specific PAB block. The module slots 
for each transmitter configuration are labeled as shown in Figure 2-3.