WARNING: Disconnect primary power prior to servicing.
Section 2 Installation / Initial Turn-On
Maxiva UAX Transmitter Indoor System
User Manual
2.6
AC Distribution Panel
!
 CAUTION:
ALL CONNECTIONS LISTED IN THIS SECTION SHOULD BE VERIFIED WITH THE 
SCHEMATICS BEFORE INITIAL TURN ON.
!
 CAUTION:
THE USE OF A SYSTEM SURGE SUPPRESSOR IS RECOMMENDED. THE SYSTEM 
SURGE SUPPRESSOR WILL BE PROVIDED BY THE CUSTOMER.
Figure 2-6  Transmitter AC Distribution Panel
Figure 2-6 shows the AC distribution panel. LPU, TCU and PAB power can be 
controlled from this panel. It is located at the top of the transmitter in the front.
STEP 1
Verify all circuit breakers on the AC distribution panel in the 
transmitter cabinet are OFF. 
STEP 2
Verify that the AC mains are disabled before proceeding.
STEP 3
Connect a safety ground cable from the ground connector shown in 
Figure 2-4 to the AC mains ground.  
STEP 4
Following all local codes hook up the 208-240 and 120VAC mains.