WARNING: Disconnect primary power prior to servicing.
Section 2 Operation
Maxiva ULX ATSC Series
User Manual
NOTE:
Always be sure that you are accessing the desired cabinet number. The cabinet 
being viewed is indicated in the upper left corner of the screen.
To get detailed information on a particular PA Module, press the Faults  button on the 
right section of the screen. The Faults button will take you to the PA Faults screen 
shown in Figure 2-9.
2.6.1
PA Faults
This screen is basically a list of all faults monitored in each PA Module.
• 
An active fault will be highlighted in RED
• 
A warning condition will be highlighted in YELLOW.
The PA Faults screen in Figure 2-9, shows that PA Module #1, in PA Cabinet #1 has no 
faults and 1 temperature warning. It also shows a power supply fault on module 3 and 
an input power warning on module 4.
NOTE:
For a detailed explanation of all PA Faults in Figure 2-9 refer to Section 6, Diag-
nostics.
Figure 2-9  PA Faults Screen (PA Module 1 Selected)
PA Modules will fault off at 200W reflected power. Also, it will display a temperature 
fault at 65° C ambient temperature (measured by a thermistor on the monitor board) or 
90° C pallet temperature.