GatesAir Inc. ULXATSC Manuel D’Utilisation
2-14
888-2715-001
2/19/10
WARNING: Disconnect primary power prior to servicing.
Section 2 Operation
Maxiva ULX ATSC Series
User Manual
NOTE:
Always be sure that you are accessing the desired cabinet number. The cabinet
being viewed is indicated in the upper left corner of the screen.
being viewed is indicated in the upper left corner of the screen.
To get detailed information on a particular PA Module, press the Faults button on the
right section of the screen. The Faults button will take you to the PA Faults screen
shown in Figure 2-9.
right section of the screen. The Faults button will take you to the PA Faults screen
shown in Figure 2-9.
2.6.1
PA Faults
This screen is basically a list of all faults monitored in each PA Module.
•
An active fault will be highlighted in RED
•
A warning condition will be highlighted in YELLOW.
The PA Faults screen in Figure 2-9, shows that PA Module #1, in PA Cabinet #1 has no
faults and 1 temperature warning. It also shows a power supply fault on module 3 and
an input power warning on module 4.
faults and 1 temperature warning. It also shows a power supply fault on module 3 and
an input power warning on module 4.
NOTE:
For a detailed explanation of all PA Faults in Figure 2-9 refer to Section 6, Diag-
nostics.
nostics.
Figure 2-9 PA Faults Screen (PA Module 1 Selected)
PA Modules will fault off at 200W reflected power. Also, it will display a temperature
fault at 65° C ambient temperature (measured by a thermistor on the monitor board) or
90° C pallet temperature.
fault at 65° C ambient temperature (measured by a thermistor on the monitor board) or
90° C pallet temperature.