18
Programming
3.
Wait at least 10 seconds but not more than 40, then call 
the panel location again. The panel should answer on 
the first ring.
If set to 1, perform steps 1 - 3 once.
If set to 2, perform steps 1 - 3 twice.
If set to 3, perform steps 1 - 3 three times.
To turn on Ring/Hang/Ring, press:
Add—Option #—27—1, 2, 3, or 4—DONE.
To turn off Ring/Hang/Ring (disable remote access), 
press:
Delete—Option #—27—DONE.
Option 28: No Delay from Keychain Touchpad 
(Default = off)
Determines whether a keychain touchpad arms the system with 
no delay (on) or not (off).
Note 
When this feature is on, the system must be disarmed 
before entering the premises, since it is disabling the 
Entry Delay. If Option 58: Remote Touchpad Arming is 
on, keychain touchpads cannot disarm the system.
To turn on No Delay from Keychain Touchpad, press:
Add—Option #—28—DONE.
To turn off No Delay from Keychain Touchpad, press:
Delete—Option #—28—DONE.
Option 29: Panel Piezo Alarms (Default = on)
Determines whether the panel piezo emits alarm sounds (on) or 
not (off).
Note 
For UL listed systems where this option is off, at least 
one UL listed external audible signal device must be 
used and Option 53: Hardwire Siren Supervision must be 
on.
To turn on Panel Piezo Alarms, press:
Add—Option #—29—DONE.
To turn off Panel Piezo Alarms, press:
Delete—Option #—29—DONE.
Option 30: Panel Panic Alarms (Default = on)
Determines whether the panel panic buttons (police, auxiliary, 
and fire) activate alarms when pressed (on), or not (off).
To turn on Panel Panic Alarms, press:
Add—Option #—30—DONE.
To turn off Panel Panic Alarms, press:
Delete—Option #—30—DONE.
Option 31: Downloader Enable (Default = on)
Determines whether the panel can be accessed using ToolBox 
(on), or not (off).
To turn on Downloader Enable, press:
Add—Option #—31—DONE.
To turn off Downloader Enable, press:
Delete—Option #—31—DONE.
Option 32: 300 Baud (Default = on)
Determines whether the baud rate used by the panel for central 
station or ToolBox communication is 300 bps (on) or 110 bps 
(off).
To turn on 300 Baud, press:
Add—Option #—32—DONE.
To turn off 300 Baud, press:
Delete—Option #—32—DONE.
Option 33: Audio Verification (Default = off)
Determines whether the system can perform 2-way voice audio 
sessions with a central station operator (on), or not (off).
Note 
Panel voice announcements are silenced during audio 
sessions. If the operator does not terminate the session 
correctly, panel announcements may not occur for up to 
90 seconds after the operator hangs up.
Note 
If this option is off, Option 47: AVM Mode and Option 48: 
Panic Talk—AVM will not work.
To turn on Audio Verification, press:
Add—Option #—33—DONE.
To turn off Audio Verification, press:
Delete—Option #—33—DONE.
Option 34: Fail to Open Report (Default = off)
Determines whether the panel sends a Fail to Open report to a 
central station or pager if the system has not been disarmed by 
the programmed time (on), or not (off).
Note 
System time must be set correctly for this feature to work.
To turn on Fail to Open Report, press:
Add—Option #—34—Hours—Minutes—DONE.
To turn off Fail to Open Report, press:
Delete—Option #—34—DONE.