UTC Fire & Security Americas Corporation Inc 910C-SIMON Manual De Usuario
Chapter 4
Programming
53
Piezo beep options
Table 24 provides piezo beep option details
Status beeps vol. 7
Determines the panel piezo volume level for status sounds such as arming, trouble, and
status beeps. Volume range is 1 (lowest) to 10 (highest).
status beeps. Volume range is 1 (lowest) to 10 (highest).
HW siren sup.
Off
Determines whether the panel monitors hardwired sirens for open conditions (on) or not
(off). If this option is turned on, sirens connected to the panel terminals require an EOL
resistor in the wire circuit. (See on page 17 for siren wiring.) If this option is turned off,
EOL resistors are not required whether sirens are connected or not.
(off). If this option is turned on, sirens connected to the panel terminals require an EOL
resistor in the wire circuit. (See on page 17 for siren wiring.) If this option is turned off,
EOL resistors are not required whether sirens are connected or not.
Speaker volume
8
Sets the volume of voice messages from the panel speaker. Volume range is 1 (lowest)
to 8 (highest).
to 8 (highest).
Silent police
panic
panic
Off
Determines whether pressing the panel police panic button causes an audible (off) or
silent (on) alarm.
silent (on) alarm.
Panel tamper
alarm
alarm
Off
Determines whether the panel activates a tamper alarm anytime the cover is opened
(On) or only when the system is armed (Off).
(On) or only when the system is armed (Off).
Alarm report
verify
verify
Off
This option determines whether the panel verifies successful alarm reports to the
central station by displaying Phone comm is OK (On), or not (Off).
central station by displaying Phone comm is OK (On), or not (Off).
Table 24. Panel piezo beeps
Activity
Piezo beep response
Arm doors and
windows
windows
Exit delay—two beeps sound every five seconds and two times per second during the last ten seconds.
Silent exit—two beeps sound at the beginning of the exit delay and two more sound just before the exit
delay expires.
Entry delay—two beeps sound every five seconds and two times per second during the last ten seconds.
Silent exit—two beeps sound at the beginning of the exit delay and two more sound just before the exit
delay expires.
Entry delay—two beeps sound every five seconds and two times per second during the last ten seconds.
Arm motion
sensors
sensors
Exit delay— three beeps sound every five seconds and three times per second during the last ten seconds.
Silent exit— three beeps sound at the beginning of the exit delay and three more sound just before the exit
delay expires.
Entry delay— three beeps sound every five seconds and three times per second during the last ten
seconds.
Silent exit— three beeps sound at the beginning of the exit delay and three more sound just before the exit
delay expires.
Entry delay— three beeps sound every five seconds and three times per second during the last ten
seconds.
Arm doors/
windows and
motion sensors
windows and
motion sensors
Exit delay— four beeps sound every five seconds and four times per second during the last ten seconds.
Silent exit— four beeps sound at the beginning of the exit delay and four more sound just before the exit
delay expires.
Entry delay— four beeps sound every five seconds and four times per second during the last ten seconds.
Silent exit— four beeps sound at the beginning of the exit delay and four more sound just before the exit
delay expires.
Entry delay— four beeps sound every five seconds and four times per second during the last ten seconds.
Disarm
One beep
Chime
Two beeps (when programmed)
Special chime
Three beeps (when programmed)
Trouble beeps
Six beeps every minute. Press STATUS to stop beeps for four hours.
No activity
a
a.
Not investigated for use by UL.
Twenty beeps every minute for five minutes (when programmed)
Table 23. Siren options (continued)
Function
Default
Description