UTC Fire & Security Americas Corporation Inc 910C-SIMON Manual De Usuario

Descargar
Página de 88
Simon XT
Installation Manual
66
X10 operation
The following sections describe how to test X10 lamp, siren, appliance, and universal module operation.
Manual lamp module control
Control panel: Press the asterisk button (*) and the unit number of the lamp module using the numeric 
buttons to test individual lamp modules 1 through 8. The panel responds with Light # on/off.  Press the 
asterisk button (*) twice to turn on all lamp modules. Press the pound button (#) twice to turn off all 
lamp modules.
Keyfob: Press the Light button repeatedly to turn all lights on and off. The panel responds with Lights 
on/off
.
Remote handheld touchpad: Press the Lights on button and the unit number of the lamp module 
using the numeric buttons to test individual lamp modules 1 through 8. The panel responds with Light 
# on/off
. Pressing the Lights on or Lights off button twice turns all the lights on or off.
X10 siren and lamp module functions
All sirens turn off when the system is disarmed or when the siren timeout expires. Siren priority is fire (highest 
priority), intrusion, and emergency. Table 35  identifies the light information for each of these siren types.
If an alarm of greater priority occurs during an alarm of lower priority, the greater priority alarm sirens sound. 
Fire alarms sound a temporal 3 pattern (0.5 seconds on, 0.5 seconds off for three beeps then 1.5 seconds off).
Note:  The X10 siren must be set to unit #9 to “hear” emergency alarms and status beeps. To hear emergency alarms only, set to 
unit #10. 
Table 35. Alarm siren and X10 light information 
Fire
Intrusion
Emergency
X10 lights
Steady
Flashing
Steady
X10 siren
Steady
Steady
Alarm beeps
Interior and  panel Siren
Temporal 3
Steady
Fast on/off