Bombardier Transportation JGA29001-6 Manual De Usuario
Doc.Id:
Status:
RELEASED
Version:
1.0
© 2014, Bombardier Inc. or its subsidiaries.
Confidential and proprietary.
Filename: JGA29001-6UserMan.docx
Page 10 of 15
1DOC-1001388
Location of cables/conductors in the proximity of the transponder (balise).
2.5 Mounting of Transponder
2.5.1 General
The transponder shall always be programmed with a default telegram in its
memory. The programming can be performed in connection to the installation or
be performed in advance.
memory. The programming can be performed in connection to the installation or
be performed in advance.
If the transponder is programmed with the default telegram in advance, it must
be checked with the documentation for the current installation that the right
individual of transponder is prepared to be mounted on right place. Check also
which mounting method should be used.
be checked with the documentation for the current installation that the right
individual of transponder is prepared to be mounted on right place. Check also
which mounting method should be used.
SAFETY REQUIREMENT:
The installation routines must either ensure that no trains allows to pass an
information location that not are approved, or ensure that ATP is not in operation
for the actual information location (construction area is set).
The installation routines must either ensure that no trains allows to pass an
information location that not are approved, or ensure that ATP is not in operation
for the actual information location (construction area is set).
Different types of crossties require different types of attachment for
transponders. The attachments are designed in a way that metal parts cause
insignificant attenuation of the transmission. The design makes the transponders
lie at the same height relative to the head of the rail, regardless of which type of
attachment that is used for mounting.
transponders. The attachments are designed in a way that metal parts cause
insignificant attenuation of the transmission. The design makes the transponders
lie at the same height relative to the head of the rail, regardless of which type of
attachment that is used for mounting.
It is absolutely forbidden to change an existing attachment or to provide new
designs without consulting Bombardier.
designs without consulting Bombardier.
Z
X
Y
Balise