3.4.6  Manual adjustment of set values
The set values for voltage, current and power are the fundamental operating possibilities of a power supply and 
hence the two rotary knobs on the front of the device are always assigned to two of the the values in manual op-
eration. Default assignment is voltage and current. 
As a fourth value there is the resistable internal resistance, for which the resistance mode (R mode) has to be 
for details. 
Set values can be entered manually in two ways: via 
rotary knob or direct input.
Entering a value changes it at any time, no matter if the DC output is switched on or off.
When adjusting the set values, upper or lower limits may come into effect. See section „3.4.4. 
Adjustment limits (Limits)“. Once a limit is reached, the display will show a note like “Limit: U-
max” etc. for 1.5 seconds next to the adjusted value.
 
► How to adjust values with the rotary knobs
1. 
First check whether the value to be changed is assigned to one of the rotary knobs. 
The main screen displays the assignment as depicted in the figure to the right.
2. 
If, as shown in the example, the assignment is voltage (U, left) and power (P, right), 
and it is required to set the power, then the assignments can be changed by tapping 
this touch area. A set of selection fields then appears. 
3. 
After successful selection, the desired value can be set within the defined limits. Selecting a digit is done by 
pushing the rotary knob which shifts the cursor clockwise (digit will be underlined): 
►How to adjust values via direct input:
1. 
In the main screen, depending on the rotary knob assignment, values 
can be set for voltage (U), current (I), power (P) or resistance (R) via 
direct input by tapping on the set/actual value display areas, e.g in the 
uppermost area of voltage. 
2. 
Enter the required value using the ten-key pad. Similar to a pocket 
calculator the key 
 clears the input.  
 
Decimal values are set by tapping the point key. For example, 54.3 V 
is set with 
 and 
.  
3. 
The display reverts to the main page and the set values take effect..