Page 54
PSI 9000 2U Series
EA Elektro-Automatik GmbH
Helmholtzstr. 31-33 • 41747 Viersen
Germany
Fon: +49 2162 / 3785-0
Fax: +49 2162 / 16230
3.5 
Remote control
3.5.1  General
Remote control is possible via the built-in analog or USB port or via one of the optional interface modules (Any-
Bus CompactCom, only with standard models of PSI 9000 2U series) or via the GPIB port (only with option 3W 
installed). Important here is that only the analog or one digital interface can be in control. It means that if, for ex-
ample, an attempt were to be made to switch to remote control via the digital interface whilst analog remote control 
is active (Pin Remote = LOW) the device would report an error via the digital interface. In the opposite direction, 
a switch-over via Pin Remote would be ignored. In both cases, however, status monitoring and reading of values 
are always possible.
3.5.2  Control locations
Control locations are those locations from where the device is controlled. Essentially there are two: at the device 
(manual operation) and outside (remote control). The following locations are defined: 
Displayed location Description
-
If neither of the other locations is displayed then manual control is active and access from 
the analog and digital interfaces is allowed. This location is not explicitly displayed
Remote
Remote control via any interface is active
Local
Remote control is locked, only manual operation is allowed.
Remote control may be allowed or inhibited using the setting 
“Allow remote control” (see „3.4.3.1. Menu “General 
Settings”“). In inhibited condition the status 
“Local” will be displayed top right. Activating the lock can be useful if  
the device is remotely controlled by software or some electronic device, but it is required to make adjustments at 
the device or deal with emergency, which would not be possible remotely.
Activating condition 
“Local” causes the following: 
If remote control via the digital interface is active (“
Remote”). then remote control is immediately terminated and 
must be reactivated at the PC once “
Local” is no longer active.
If remote control is via the analog interface is active (“
Remote”) then remote operation is only interrupted until 
remote control is allowed again, because pin “Remote” continues to signal “remote control = on”. Exception: if 
the level of pin “Remote” is changed to HIGH during the “
Local” phase.
3.5.3  Remote control via a digital interface
3.5.3.1  Selecting an interface
The standard models of series PSI 9000 2U support, in addition to the built-in USB port, the following optional ly 
available interface modules:
Short ID
Art. nr.
Type
Ports Description*
IF-AB-CANO
35400100 CANopen
1
CANopen slave with generic EDS
IF-AB-RS232
35400101 RS232
1
Standard RS232, serial
IF-AB-PBUS
35400103 Profibus
1
Profibus DP-V1 slave
IF-AB-ETH1P
35400104 Ethernet
1
Ethernet TCP
IF-AB-PNET1P
35400105 ProfiNet
1
Profinet DP-V1 slave
IF-AB-DNET
35400106 Devicenet
1
Full Devicenet slave
IF-AB-MBUS
35400107 ModBus TCP 1
ModBus-Protocol via Ethernet
IF-AB-ETH2P
35400108 Ethernet
2
Ethernet TCP, with switch
IF-AB-MBUS2P
35400109 ModBus TCP 2
ModBus-Protocol via Ethernet
IF-AB-PNET2P
35400110 ProfiNet
2
Profinet DP-V1 slave, with switch
* For technical details of the various modules see the extra documentation “Programming Guide Modbus & SCPI”
Models with option 3W installed offer an additional pre-installed GPIB port next to the default USB port.