Geo PCK-EN-005 Hoja De Datos
20
16. General notes
• If the transmitter symbol on the display is not lighting permanently, a problem with the radio communication
occurred. Connecting transmitter and display („PAIRING“) should be conducted again.
• The voltage is measured with the SmartPlug number 1. Without SmartPlug the standard voltage is assumed.
• Voltage and current phase is not measured exactly synchronous. It is assumed a regular household with
miscellaneous consumption and a regular CosPhi by 1. For strongly uncompensated reactive power consumption
this product will have an appropriate deviation to the utility meter.
this product will have an appropriate deviation to the utility meter.
• At the display a percentage correction factor (C-factor) can be set. With this measuring tolerances to the utility meter
can be equalized.
• The CO
2
value is deducted of a fixed constant. The constant is embedded in the specifications and cannot be
modified in the current version. A configuration according to e.g. grey or green power is planned for a future release.
17. Disposal
To protect the environment, these products and batteries must be disposed of safely at the end of their
life. Please take to a recycling centre for safe disposal.
life. Please take to a recycling centre for safe disposal.
18. Declaration of Conformity (DOC)
We, Conrad Electronic, Klaus-Conrad-Straße 1, D-92240 Hirschau, hereby declare that this product adheres to the
fundamental requirements and other relevant regulations of the directive 1999/5/EC.
fundamental requirements and other relevant regulations of the directive 1999/5/EC.
The compliance statement for this product is available at www.conrad.com.