Geo PCK-EN-005 Hoja De Datos

Descargar
Página de 24
21
19. Technical data
a) Display
Dimensions ......................................... approx. 150 x 80 x 15 mm
Features .............................................. Display total consumption, consumption and control (incl. timer) for up to 6
appliances
Memory ............................................... Recording current day, each of the last 7 days, sum for last week and for last
4 weeks
Power consumption ............................ < 1 W
Power supply ...................................... Power supply unit, 230 V/AC, 50 Hz
Radio protocol ..................................... 868 MHz, manufacturer specific
Screen ................................................. LC display, active area ca. 100 x 60 mm
Operation ............................................ 4 buttons, functionalities see manual
CO
2
 Equivalent ................................... 537 g/kWh
b) Transmitter
Sensors ............................................... Item no. 388753: split-core ferrite current clamps, max 75 Amp , 50 Hz,
Cat III
Item no. 398754: optical sensor for LED and IR light, Velcro fixing
Accuracy .............................................. ± 5 % resistive loads, sinusoidal waveform (cos phi = 1)
Dimensions ......................................... approx. 110 x 70 x 30 mm
Temperature range ............................. -20 °C to +50 °C, at 85% rel. humidity, non-condensing
Battery lifetime .................................... > 1 year
Battery type ......................................... 3 x AA-Batteries, Alkaline
Radio protocol ..................................... 868 MHz, manufacturer specific
Radio transmission ............................. ca. 0,1 % modulation, attenuation max. +3 dBm
Operation ............................................ Pair button, control LED
Measurement ...................................... 10 bit ADC, 75 kW full scale, nonlinear cos-phi compensation
Measuring interval .............................. 2 seconds
Data transmission ............................... 2 second minimum, triggered by a load change of > 25 W