Fig. 41  Remove and replace injector orifices.
ST353a
injector orifice
replace
3/21/00    djt
90°
Left Burner Leg
Injector Orifices
ST353a
Complete the Assembly
• 
Open the swiveling latches (cams) on the top left 
and right corners of the glass frame.
• 
Position the glass and frame against the firebox by 
placing the bottom edge on the brackets on the bot-
tom face of the firebox.
• 
Swing the assembly against the firebox, and close 
the latches firmly against the pins protruding from 
the firebox top.
Install ON/OFF Switch
The switch assembly parts are found in the parts bag.
1.  Attach switch assembly to left rear side of stove 
shroud (when facing shroud) using two screws and 
existing holes in shroud. (Fig. 42)
2.  Run wires down back of stove, under bottom of rear 
shroud to valve.
3.  Attach wires to valve terminals. (Fig. 43)
PILOT
ADJ
TP
TH
TPTH
ST228
attach switch
wires to valve
12/99
ST228
Fig. 43  Attach switch wires to valve.
ST315
attach switch assy
1/31/00   djt
Switch As-
sembly
Screws
Existing 
Holes
ST315
Fig. 42   Attach switch assembly to rear shroud.
Install the Stove Front
The front panel attaches to the stove by four (4) steel 
tabs that engage with corresponding cast ribs on the 
sides and bottom of the stove body. Position the front 
about 3” down from the stove top and lift the plate to 
engage the upper tabs behind the adjacent ribs on the 
side. (Fig. 44) Then lower the plate into position, so the 
lower tabs engage with the corresponding ribs at the 
bottom. (Fig. 45)
When properly installed, the bottom of the stove front 
cannot be pulled away from the sides without also lifting 
it.
ST229
FDV28 attach Front
12/8/99   djt
3”
(76 mm)
Control 
Door
Lower Tabs Engage 
Ribs in bottom
Upper Tabs
ST229
Fig. 44  Install stove front.
ST279
front plate top view
1/19/00   djt
Side Rib
Front Tab
Stove Side
Stove Front
ST279
Fig. 45  Engage with side ribs.
Thermostat Connection (optional)
Use only a thermostat rated for 500 - 750 millivolts.
Check the table below for the appropriate gauge ther-
mostat wire to use for the length of lead required in your 
installation.
1.  Install the wall thermostat in the desired location and 
run the wires to the stove location. Terminate these 
leads with 1/4” female connectors.
2.  Connect the thermostat wires to the valve.  (Fig. 43)
 
Thermostat  
 
 
Wire / Gauge 
Maximum Run
 
18 
20 feet
 
16 
20 - 40 feet
 
14 
up to 60 feet