Vulcan-Hart Home Heaters Manual De Usuario

Descargar
Página de 37
 
Copyright 2005                                                                                    
20
                                
Vulcan V SERIES 
 Owner’s Manual 
Canadian Comfort Industries                                      
                                                     
T
HE 
A
CU
T
RON 
C
ONTROLS
 
 
Basic Overview 
The AcuTron II or III digital control board was designed to give you flexibility on how 
you want to operate your stove.  The AcuTron can be operated as a MANUAL 
control or by a THERMOSTAT.  When operating in the Thermostat option, you can 
also choose to run your appliance in the ON/OFF mode or the LOW/HIGH mode. 
 
The START or FEED RATE touch pad allows electricity to flow to your stove's 
electrical components for 15 minutes.  If after 15 minutes your stove has heated to 
normal operating temperatures your stove will continue to run.  If the fire does not 
light and/or burn properly, the electricity to your stove's components will be shut off 
at the end of 15 minutes. 
 
The FAN SPEED controls the speed of the room air fan.  This fan blows room air 
through the heat exchange tubes and back into the room.  When the FEED RATE is 
set to a higher position, the FAN SPEED should be set higher and visa versa.  To 
achieve optimum heat transfer it is recommended to set the FAN SPEED to  LOW or  
LOW/MED when running the FEED RATE at 1 or 2, and Fan on MED OR 
MED/HIGH on FEED RATE #3 or 4. 
 
When the START / FEED RATE is ON, the AUGER CYCLE LED will turn on when 
the auger is active.  When the OFF touch pad is pushed [OFF], the auger motor will 
not run, fuel stops feeding and the fire will die. 
 
The FEED RATE works in a synchronized manner setting both the fuel rate and 
combustion air at the same time.  When fuel is increased by setting the FEED RATE 
higher, combustion air is automatically increased and visa versa. 
 
HOW THE BOARD WORKS 
 
I
NITIAL 
START
 OR 
S
ET
-
UP 
(M
ANUAL OR 
N
ON
-T
HERMOSTAT 
M
ODE
 
Upon initial start-up the control will feed automatically at the #1 feed rate. 
Press  the START touch pad. 
- Convection 
(heating) 
fan will start and the FAN LED will be solid on LOW setting 
The 300 watt  Auto-Igniter will begin to glow and the IGNITER LED will be solid  
- The 
AUGER CYCLE LED will go solid for 3 seconds, indicating signal is being sent to the auger motor. 
The Combustion (exhaust) fan will start and operate at full speed for 60 seconds, then adjust downward to match 
feed rate #1. 
Press FEED RATE touch pad to select desired heat output that you require upon completion of ignition sequence. 
 
NOTE:
 If you do not press the FEED RATE touch pad, the stove will continue to run at FEED RATE #1 and the LED will continue 
to flash at a fast rate. 
When the FEED RATE LED is flashing at a FAST rate this indicates that the LOW LIMIT (L120) is closed. This means 
the unit has not reached operating temperature. 
When the FEED RATE LED is flashing at a SLOW rate this indicates that the LOW LIMIT (L120) is open. This means 
the control board has entered a 5 minute “Safety Delay” mode.   
 
After the 5 minute Safety Delay is complete 
IGNITER and INGNITER LED will turn off 
FEED RATE LED will become solid and the appliance will feed fuel at your selected heat output 
 
R
E
-S
TART 
(M
ANUAL OR 
N
ON
-T
HERMOSTAT 
M
ODE
 
The AcuTron II or III board does have limited memory.  To restart your appliance push the START touch pad.  The appliance will 
automatically go through it normal start-up then return to the FEED and FAN setting you used prior to turning off the board and 
appliance the last time of use.