Royal Appliance Air Furnace Manual De Usuario

Descargar
Página de 40
 
29733 R2  06/01/2003
 
7
Figure 2: Common Chimney Problems 
6.  CHIMNEY VENTING 
The chimney must be sized correctly and be in good 
repair. If the chimney is oversized, there is a high risk of 
the flue gases condensing resulting in damage to the 
chimney and other venting parts. This problem may be 
corrected by the use of an appropriately sized chimney 
liner. 
 
If the chimney serves the furnace only, the vent should 
be sized at 4 inch minimum, 5 inch maximum. The table 
below is based on dedicated venting. If the furnace is to 
be co-vented with other appliances, refer to NFPA 31
Standard for the Installation of Oil Burning Equipment and 
NFPA 211,  Standard for Chimneys, Fireplaces, Vents, 
and Solid Fuel-Burning Appliances
 or CAN/CSA B139
Installation Code For Oil Burning Equipment for correct 
sizing information 
 
Table 3: Common Chimney Problems 
Refer to Figure 2 
Key Trouble  Diagnostic  Remedy 
Top of chimney 
lower than 
surrounding  
objects 
Observation 
Extend 
chimney above 
all surrounding 
objects within 
30 feet. 
Chimney Cap 
or ventilator. 
Observation Remove 
Coping restricts 
opening. 
Observation 
Make opening 
as large as 
inside of 
chimney. 
Obstruction in 
chimney  
 
 
Can be found  
by light and 
mirror reflecting 
conditions in 
chimney. 
Use weight to  
break and 
dislodge. 
Joist protruding 
into chimney. 
Lowering a light 
on an extension 
cord. 
Must be 
handled by 
competent 
masonry 
contractor. 
Break in 
chimney lining. 
Smoke test - 
build smudge 
fire blocking off 
other opening, 
watching for 
smoke to 
escape. 
Must be 
handled by 
competent 
masonry 
contractor. 
Collection of 
soot at narrow 
space in flue 
opening. 
Lower light on 
extension cord. 
Clean out with 
weighted brush 
or bag of loose 
gravel on end 
of line. 
H Offset 
Lower light on 
extension cord. 
Change to 
straight or to 
long offset. 
Two or more 
openings to the 
same chimney. 
Found by 
inspection from 
basement. 
The least 
important 
opening must 
be closed, 
using some 
other chimney 
flue. 
Loose-seated 
pipe in flue 
opening. 
Smoke test. 
Leaks should 
be eliminated 
by cementing 