Philips 8-bit microcontroller with two-clock 80C51 core UM10109 Manual De Usuario

Descargar
Página de 133
 
© Koninklijke Philips Electronics N.V. 2005. All rights reserved.
User manual
Rev. 02 — 23 May 2005 
42 of 133
Philips Semiconductors
UM10109
P89LPC932A1 User manual
 
7.6 Timer overflow toggle output
Timers 0 and 1 can be configured to automatically toggle a port output whenever a timer 
overflow occurs. The same device pins that are used for the T0 and T1 count inputs and 
PWM outputs are also used for the timer toggle outputs. This function is enabled by 
Fig 16. Timer/counter 0 or 1 in Mode 2 (8-bit auto-reload).
002aaa921
PCLK
Tn pin
TRn
gate
INTn pin
C/T = 0
C/T = 1
TLn
(8-bits)
THn
(8-bits)
TFn
control
ENTn
Tn pin
toggle
overflow
interrupt
reload
Fig 17. Timer/counter 0 Mode 3 (two 8-bit counters).
002aaa922
PCLK
osc/2
T0 pin
TR0
TR1
gate
INT0 pin
C/T = 0
C/T = 1
TL0
(8-bits)
TF0
control
ENT0
(AUXR1.4)
T0 pin
(P1.2 open drain)
toggle
overflow
interrupt
TH0
(8-bits)
TF1
control
ENT1
(AUXR1.5)
T1 pin
(P0.7)
toggle
overflow
interrupt
Fig 18. Timer/counter 0 or 1 in mode 6 (PWM auto-reload).
002aaa923
PCLK
TRn
gate
INTn pin
C/T = 0
TLn
(8-bits)
THn
(8-bits)
TFn
control
ENTn
Tn pin
toggle
overflow
interrupt
reload THn on falling transition
and (256 