F-2200 Series Vortex Flow Meter Installation and Operation Guide • Revised 12/08
ACCURACY 
 Volumetric 
fl ow    
 
 
±1% of reading accuracy (±2% for ¾” & smaller sizes) 
 Mass 
fl ow    
 
 
±1.5% of reading accuracy (±2.5% for ¾” & smaller sizes)  
OPERATING TEMPERATURE RANGE 
 Media 
temperature    
 
 
25° to 464° F  
 Ambient 
temperature    
 
 
0° to 132° F   
DISPLAY / USER INTERFACE 
 
16x64 dot matrix LCD with 3 button keypad and magnetic pin programming  
OUTPUT SIGNALS 
 Rate:   4-20mA, loop-powered  
 
 
Supply voltage range: 14-36 VDC 
 
 
Minimum load resistance: 100 ohms  
 
 
Maximum load resistance is calculated as follows:    
 
 
Max load  = Vs – 12V           Where Vs = supply voltage                                         
 
 
 
         0.020A  
 Total:  Scaled output pulse, programmable  
 
 
Optically isolated open collector, 0.5 hz maximum  
 
 
Rating: 5-36 VDC, 100mA maximum  
SUPPLY VOLTAGE: 
 
14-36 VDC  
PROCESS CONNECTIONS: 
 
Standard: 
ANSI #300 fl anges 
 
Optional: 
ANSI #600 fl anges   
APPROVALS 
 
Safety:  
Conforms to CE mark as per LVD, PED and EMC Directive 
 
Enclosure: 
Conforms to IP 65 and IP 67