Chapter 2
Function Reference — WFM_Group_Control
©
 National Instruments Corporation
2-421
NI-DAQ FRM for PC Compatibles
Note
If you invoke this function to clear continuous waveform generation that was 
stopped previously because of an underflow error, 
WFM_Group_Control
 does not 
report the occurrence of the underflow error. If you want to check for this type of 
error, invoke function 
WFM_Check
 prior to invoking 
WFM_Group_Control
 to 
clear waveform generation.
Note
For the MIO-16/16D, counter 2 must be available in order to use waveform 
generation. If an interval scan is in progress (see 
SCAN_Start
) or a 
CTR
 function 
is using counter 2, waveform generation cannot proceed.
For Lab and 1200 Series analog output devices, if the rate is smaller than 
15.26 pts/s and counter B0 is busy in a data acquisition operation, waveform 
generation cannot proceed.
For the AT-MIO-16F-5, AT-MIO-64F-5, and AT-MIO-16X, one of the counters 
1, 2, or 5 must be available. NI-DAQ uses the first available counter among 
counters 5, 2, and 1, in that order. If counter 5 is in use, and NI-DAQ if forced to 
use counters 2 or 1, a RTSI line must also be available.
On Am9513-based MIO devices, to trigger a waveform generation operation 
externally, you can do so by first changing the gating mode of the counter 
NI-DAQ uses.
On Am9513-based MIO devices, 
WFM_OP
 uses either the default gating mode 
(none) or the gating mode you specify through the 
CTR_Config
 function. You 
need to connect your trigger signal to the gate pin on the I/O connector.
operation = 2 (PAUSE):
Temporarily halts waveform generation for the group of 
channels. NI-DAQ maintains the last voltage written to the 
DAC indefinitely.
Note
This value of operation = 2 is not supported for the AT bus E Series devices 
(except the AT-MIO-16XE-10), the 4451 devices, the 4551 devices, or the 
DAQArb 5411 devices. 
operation = 4 (RESUME): Restarts waveform generation for the group of channels that 
previously halted by operation = PAUSE.
Note
This value of operation = 4 is not supported for the AT bus E Series devices 
(except the AT-MIO-16XE-10), the 4451 devices, the 4551 devices, or the 
DAQArb 5411 devices. 
When you have halted a waveform generation by executing PAUSE, RESUME restarts the 
waveform exactly at the point in your buffer where it left off. If n iterations of the buffer 
remained to be completed when you executed operation = PAUSE, those n iterations are